Source Kits for Siemens Medical Solutions® PET Scanners

Source replacement kit Includes: PET-180/1 (2 ea), PET20C27/2

Order Number Description Activity (Ge-68) Qty Recommended Replacement cycle
BIO-R (Source Kit for Biograph™) Source replacement kit Includes: PET-180/1 (2 ea), PET20C19/1 Various Kit 12 months
BIOH-R (Source Kit for Biograph Pico™) Source replacement kit Includes: PET-180/1 (2 ea), PET20C19/2 Various Kit 12 months
BIV-R (Source Kit for Biograph True-V™ and mCT™) Source replacement kit Includes: PET-180/1 (2 ea), PET20C27/ Various Kit 12 months
BIO-S (Supplementary Startup Kit for all Dedicated PET) Startup Source supplement kit Includes: PET-180/1, PET20C19/1 Various Kit 12 months
ACL-R (Accel™ Source Kit)  Source annual replacement kit Includes PET-168/5 (3 ea), PET-20C19/3 Various Kit 12 months
HRP-R (HR+™ Source Kit) Source annual replacement kit Includes: PET-168/3.8 (3 ea), PET-20C19/3 Various Kit 12 months
EXT-R (Exact™ Source Kit) Source annual replacement kit Includes: PET-168/3.3 (3 ea), PET-20C19/3 Various Kit 12 months

Individual Sources for Siemens PET Scanners

Order Number Description Activity (Ge-68) Recommended Replacement cycle
PET-168/5 Transmission rod 185 MBq (5 mCi) 12 months
PET-168/3.8 Transmission rod 141 MBq (3.8 mCi) 12 months
PET-168/3.3 Transmission rod 122 MBq (3.3 mCi) 12 months
PET-180/1 Calibration rod source 44 MBq (1.2 mCi) 12 months
PET-20C19/1 Cylinder phantom 44 MBq (1.2 mCi) 12 months
PET-20C19/2   Cylinder phantom 74 MBq (2 mCi) 12 months
PET-20C19/3   Cylinder phantom 120 MBq (3.2 mCi) 12 months
PET-20C27/2 Cylinder phantom for extended FOV 74 MBq (2 mCi) 12 months
PET-20C30/3-MR Cylinder phantom for PET/MR 111 MBq (3 mCi) 12 months
PET-281/1.5-MR   Calibration Rod Source for PET/MR 55 MBq (1.5 mCi) 12 months

Standard Source Features

  • Non-Uniformity measurement is less than or equal to ±5%. Test scans provided
  • Leak test certificate
  • Lifetime warranty
  • Documents/labels for return(s) supplied upon request
  • Activity tolerance ±15%

Rod Sources

  • Double encapsulated stainless steel or titanium tubing
  • Permanent laser markings
  • Laser welded ends
  • ANSI rating C32312
  • Supplied in lead container

Cylinder Phantom

  • ANSI rating C22212
  • µ value=0.1029
  • Quarter section slice marks

Deliveries

Four weeks after receipt of order. Expedited deliveries are available upon request.

Licenses (U.S. Only)

Valid copies of customer’s radioactive materials license or registration must be on file with SMP prior to shipment. SMP shipping containers are D.O.T. and IATA compliant.

Sealed Source Device Registry (SSDR)

ITS Medical Product’s SSDR for the rod source is TN-0241-S-101-S. SMP’s SSDR for the cylinder phantom source is TN-0241-S-102-S. License amendment guides can be downloaded from here. Ge-68 sources are available for older, discontinued Siemen camera systems as well as current models.